Proliant

Presentation

Find all the service models dedicated to the supervision of your Server - Server Proliant.

Service Templates

BOX mode

HP-Proliant-HardwareStatus-iLO_nofansred

Checks the hardware status of an HP Proliant server using the iLO management card by logging into the iLO website. Items checked include: disks, critical events in the iLO log, temperature sensors against manufacturer thresholds, power supply redundancy. The check does not collect temperature performance data.
Configuration: account and password of a user authorized to connect to the iLO card website, iLO website port, iLO version, SSL version, SSL options, check execution time.

Available from version 4.15

HP-ProLiant-Raid-Cache

Collects battery information for the HP ProLiant server RAID controller cache. Battery pack being recharged or a failed battery in the pack causes the service to enter the Alert state. Battery pack that has not been recharged for more than 36 hours causes the service to enter the Critical state. Prerequisite: HP Insight Management Agent. Configuration: SNMP community defined in HP Insight Management Agent.

Available from version 3.13

HP-ProLiant-Temperature

Measures the temperature at the sensors in an HP ProLiant server, and notifies when thresholds, defined by the manufacturer, are exceeded. Prerequisite: HP insight management agent Configuration: from the insight management agent community 

Available from version 3.13

HP-ProLiant-Fan

Tests fan operation for HP ProLiant servers and notifies in case of failure. Prerequisite: HP insight management agent Configuration: SNMP community 

Available from version 3.13

HP-ProLiant-Power_Supply

Tests power supplies on HP ProLiant servers and returns the number of working and failed power supplies. Notifies when a power supply is faulty. Prerequisite: HP insight management agent Configuration: SNMP community 

Available from version 3.13

HP-ProLiant-Raid

Tests the status of the disks that make up the RAID system for HP ProLiant servers and notifies when a disk is not functioning. Prerequisites: HP insight management agent Configuration: from the insight management agent community 

Available from version 3.13

HP-Proliant-ControllersDriveCache-Status

Collects the status of disk write caches on all disk controllers on an HP Proliant system, except those that are excluded. Monitoring becomes critical when at least one of the caches is disabled, or its status is unavailable. Configuration: SNMP community, SNMP port, serial number of the controllers to exclude.

Available from version 3.13

HP-Proliant-Controllers-Status

Collects the global status of disk controllers on an HP Proliant system, except for serial numbers in the exclusion list. The global status includes the status of logical and physical disks, and accelerators. Configuration: SNMP community, SNMP port, serial number of the controllers to be excluded.

Available from version 3.13

HP-Proliant-HardwareStatus-iLO

Checks the hardware status of an HP Proliant server using the iLO management card by logging into the iLO website. Items checked include: fan redundancy, disks, critical events in the iLO log, temperature sensors against manufacturer thresholds, power supply redundancy. The check does not collect temperature performance data.
Configuration: account and password of a user authorized to connect to the iLO card website, iLO website port, iLO version, SSL version, SSL options, check execution time.

Available from version 3.13

AGENT mode

A-HP-Dataprotector Express

Analyzes backups performed with HP Data Protector Express software. Changes to Alert status when at least one backup job is in WARNING status during the period. Changes to Critical status when no backup jobs were performed during the period, or when at least one backup job is in ERROR status during the period. Configuration: configure HP Dataprotector Express to insert notifications into the Windows Application event log.

Available from version 3.13

A-HP-ProLiant-Fans

Tests fan operation for HP ProLiant servers and notifies in case of failure. Prerequisite: HP insight management agent. Requirements: none.

Available from version 3.13

A-HP-ProLiant-Powersupply

Tests power supplies on HP ProLiant servers and returns the number of working and failed power supplies. Notifies when a power supply is faulty. Prerequisite: HP insight management agent Configuration: none.

Available from version 3.13

A-HP-ProLiant-Raid

Tests the status of the disks that make up the RAID system for HP ProLiant servers and notifies when a disk is not functioning. Prerequisites: HP insight management agent Configuration: none.

Available from version 3.13

A-HP-ProLiant-Sensors

Measures the temperature at the sensors in an HP ProLiant server, and notifies if the thresholds, defined by the manufacturer, are exceeded. Prerequisite: HP insight management agent. Configuration: none.

Available from version 3.13
en_GB

Our next events

Our upcoming webinars

Our Previous Webinars

Welcome to ServiceNav!

Do you need some help? More information about our products? Write to us!
We will never sell or share your personal data with third parties. You have taken note of our privacy policy.
We use cookies to ensure the best experience on our site. If you continue to use this site, we will assume that you are satisfied with it.

Reserve your place

We will never sell or share your personal data with third parties. You have taken note of our privacy policy.