Find all the service models dedicated to the supervision of your Server - Server Proliant.
Proliant
Presentation
Service Templates
BOX mode
HP-Proliant-HardwareStatus-iLO_nofansred
Checks the hardware status of an HP Proliant server using the iLO management card by logging into the iLO website. Items checked include: disks, critical events in the iLO log, temperature sensors against manufacturer thresholds, power supply redundancy. The check does not collect temperature performance data.
Configuration: account and password of a user authorized to connect to the iLO card website, iLO website port, iLO version, SSL version, SSL options, check execution time.
Available from version 4.15
HP-ProLiant-Raid-Cache
Collects battery information for the HP ProLiant server RAID controller cache. Battery pack being recharged or a failed battery in the pack causes the service to enter the Alert state. Battery pack that has not been recharged for more than 36 hours causes the service to enter the Critical state. Prerequisite: HP Insight Management Agent. Configuration: SNMP community defined in HP Insight Management Agent.
Available from version 3.13
HP-ProLiant-Temperature
Measures the temperature at the sensors in an HP ProLiant server, and notifies when thresholds, defined by the manufacturer, are exceeded. Prerequisite: HP insight management agent Configuration: from the insight management agent community
Available from version 3.13
HP-ProLiant-Fan
Tests fan operation for HP ProLiant servers and notifies in case of failure. Prerequisite: HP insight management agent Configuration: SNMP community
Available from version 3.13
HP-ProLiant-Power_Supply
Tests power supplies on HP ProLiant servers and returns the number of working and failed power supplies. Notifies when a power supply is faulty. Prerequisite: HP insight management agent Configuration: SNMP community
Available from version 3.13
HP-ProLiant-Raid
Tests the status of the disks that make up the RAID system for HP ProLiant servers and notifies when a disk is not functioning. Prerequisites: HP insight management agent Configuration: from the insight management agent community
Available from version 3.13
HP-Proliant-ControllersDriveCache-Status
Collects the status of disk write caches on all disk controllers on an HP Proliant system, except those that are excluded. Monitoring becomes critical when at least one of the caches is disabled, or its status is unavailable. Configuration: SNMP community, SNMP port, serial number of the controllers to exclude.
Available from version 3.13
HP-Proliant-Controllers-Status
Collects the global status of disk controllers on an HP Proliant system, except for serial numbers in the exclusion list. The global status includes the status of logical and physical disks, and accelerators. Configuration: SNMP community, SNMP port, serial number of the controllers to be excluded.
Available from version 3.13
HP-Proliant-HardwareStatus-iLO
Checks the hardware status of an HP Proliant server using the iLO management card by logging into the iLO website. Items checked include: fan redundancy, disks, critical events in the iLO log, temperature sensors against manufacturer thresholds, power supply redundancy. The check does not collect temperature performance data.
Configuration: account and password of a user authorized to connect to the iLO card website, iLO website port, iLO version, SSL version, SSL options, check execution time.
Available from version 3.13
AGENT mode
A-HP-Dataprotector Express
Analyzes backups performed with HP Data Protector Express software. Changes to Alert status when at least one backup job is in WARNING status during the period. Changes to Critical status when no backup jobs were performed during the period, or when at least one backup job is in ERROR status during the period. Configuration: configure HP Dataprotector Express to insert notifications into the Windows Application event log.
Available from version 3.13
A-HP-ProLiant-Fans
Tests fan operation for HP ProLiant servers and notifies in case of failure. Prerequisite: HP insight management agent. Requirements: none.
Available from version 3.13
A-HP-ProLiant-Powersupply
Tests power supplies on HP ProLiant servers and returns the number of working and failed power supplies. Notifies when a power supply is faulty. Prerequisite: HP insight management agent Configuration: none.
Available from version 3.13
A-HP-ProLiant-Raid
Tests the status of the disks that make up the RAID system for HP ProLiant servers and notifies when a disk is not functioning. Prerequisites: HP insight management agent Configuration: none.
Available from version 3.13
A-HP-ProLiant-Sensors
Measures the temperature at the sensors in an HP ProLiant server, and notifies if the thresholds, defined by the manufacturer, are exceeded. Prerequisite: HP insight management agent. Configuration: none.