Find all the service models dedicated to the monitoring of your Server - Server Proliant.

Proliant
Presentation
Service Templates
BOX mode
HP-Proliant-HardwareStatus-iLO
Checks the hardware status of an HP Proliant server using the iLO administration card by logging on to the iLO website. Items checked include: fan redundancy, disk redundancy, critical events in the iLO log, temperature sensors based on manufacturer thresholds, power supply redundancy. The control does not collect temperature performance data.
Configuration : account and password of a user authorized to log on to the iLO card website, iLO website port, iLO version, SSL version, SSL options, check execution time.
Available from version
3.13
HP-Proliant-ControllersDriveCache-Status
Collects the status of disk write caches on all disk controllers on an HP Proliant system, except those excluded. Control becomes critical when at least one of the caches is disabled, or its status is unavailable. Configuration: SNMP community, SNMP port, serial number of controllers to be excluded.
Available from version
3.13
HP-Proliant-Controllers-Status
Collects the overall status of disk controllers on an HP Proliant system, except for serial numbers listed in the exclusion list. The global status includes logical and physical drives and accelerators. Configuration: SNMP community, SNMP port, serial numbers of controllers to exclude.
Available from version
3.13
HP-ProLiant-Fan
Tests fan operation for HP ProLiant servers and notifies in case of failure. Prerequisite: HP insight management agent Configuration: SNMP community
Available from version
3.13
HP-ProLiant-Power_Supply
Tests power supplies on HP ProLiant servers and returns the number of functional and faulty power supplies. Notifies when a power supply fails. Prerequisite: HP insight management agent Configuration: SNMP community
Available from version
3.13
HP-ProLiant-Raid
Tests the status of the disks that make up the RAID system for HP ProLiant servers and notifies when a disk is not working. Prerequisite: HP insight management agent Configuration: from the insight management agent community
Available from version
3.13
HP-ProLiant-Raid-Cache
Collects information about the RAID controller cache battery on HP ProLiant servers. A battery pack being recharged or a defective battery in the pack causes the service to enter an Alert state. A battery pack that has not been recharged for more than 36 hours causes the service to enter a Critical state. Prerequisite: HP Insight Management Agent. Configuration: SNMP community defined in HP Insight Management Agent.
Available from version
3.13
HP-ProLiant-Temperature
Measures the temperature at the sensors in an HP ProLiant server and notifies if the thresholds, defined by the manufacturer, are exceeded. Prerequisite: HP insight management agent Configuration: from the insight management agent community
Available from version
3.13
AGENT mode
A-HP-Dataprotector Express
Analyzes backups made with HP Data Protector Express software. Switches to Alert status when at least one backup job is in WARNING status over the period. Goes to Critical status when no backup job has been performed during the period, or when at least one backup job is in ERROR status during the period. Configuration: Configure HP Dataprotector Express to insert notifications in the Windows Application Event Log.
Available from version
3.13
A-HP-ProLiant-Fans
Tests fan operation for HP ProLiant servers and notifies in case of failure. Prerequisite: HP insight management agent. Configuration: None.
Available from version
3.13
A-HP-ProLiant-Powersupply
Tests power supplies on HP ProLiant servers and returns the number of functional and faulty power supplies. Notifies when a power supply fails. Prerequisite: HP insight management agent Configuration: none.
Available from version
3.13
A-HP-ProLiant-Raid
Tests the status of the disks that make up the RAID system for HP ProLiant servers and notifies when a disk is not working. Prerequisite: HP insight management agent Configuration: none.
Available from version
3.13
A-HP-ProLiant-Sensors
Measures the temperature at the sensors in an HP ProLiant server and notifies if the thresholds, defined by the manufacturer, are exceeded. Prerequisite: HP insight management agent. Configuration: None.
Available from version
3.13
News
The supervision of servers at the heart of your company
18 November 2020
Integration with Slack: Why and How?
10 April 2020
Why monitor an Office365 environment?
9 April 2020
8 April 2020
Need some help?